Large Flow Duplex Filter/Pipeline water Filter for water treatment system .
The feature of duplex oil strainer allows for continuous operation when changing elements due to clogging caused by contaminants. After opening the balance valve and turning the directional valve, the other filter begins to work, thus a clogged element should be changed in time. These series of duplex basket strainer have a high flow range from 1300 l/min to 15000 l/min with maximum pressure 1.6 Mpa. They are widely used in the hydraulic systems of heavy-duty mining and metallurgical machines. Note: As the leading duplex strainer manufacturer in China , Lilt filter can custom any duplex basket strainers based your detailed requirement.
Apllication
Drawing
Operating steps
Operating Steps of Large Flow Duplex Filter/Pipeline water Filter for water treatment system
1. Install the duplex basket filter in the working system. 2. After completing filter installation, open the inlet and outlet valves of the filter; the system will start working. 3. When the CMS-I alarm turns on (differential pressure is achieved 0.35MPa), please change the switch valve and let the spare filter work. 4. Open the vent valve (on the upper cap) and blow-down valve (on the bottom cap); let the dust fluid drain off the filter completely. 5. Open its upper can and take out the filter element. 6. Clean or change the filter element, then install the filter element and upper cap. 7. Close the vent valve and blow-down valve. Make it a spare filter you can use once again for replacement.
Details
Models
Model
Diameter (mm)
Flow Rate (L/min)
Filtration (μm)
Pressure (Mpa)
By-pass setting (Mpa)
Pressure loss (Mpa)
Element Number
LTDF-1300
DN 100
1300
3,5,10,20,25,50,100
1.6
0.4
≤0.35
1*2
LTDF-2600
DN150
2600
2*2
LTDF-3900
DN200
3900
3*2
LTDF-6500
DN250
6500
5*2
LTDF-7800
DN250
7900
6*2
LTDF-9100
DN250
9100
7*2
LTDF-15000
DN300
15000
10*2
LTDN-1300
DN 40-100
1300
3,5,10,20,40,50,100,200
1.6
0.4
≤0.35
1*2
LTDN-1320
DN 40-125
1320
1*2
LTDN-2500
DN 50-150
2500
3*2
LTDN-4000
DN 80-200
4000
5*2
LTDN-5200
DN 80-250
5200
4*2
LTDN-6500
DN 100-250
6500
5*2
LTDN-7800
DN 100-250
7800
6*2
LTDN-15000
DN 200-300
15000
10*2
Notice
Notice of Large Flow Duplex Filter/Pipeline water Filter for water treatment system
You must know the exact positions of our duplex strainer – upper is the inlet and lower is an outlet after installation.
1. Change the filter cartridges in time when the CMS-I alarm is on and let the filter be in standby state. 2. Switch valve must be in place. 3. Have the new filter cartridge ready and know when to change it. Reduce the time interval when the internal components of the filter are exposed. 4. Ensure the seals are in good-working condition whenever you change the cartridge. Don’t forget to put the seals during installation. 5. Don’t let anything fall into the filter after opening the cover.